DeWALT Power Month! Stack up your savings now👉 Grab your FREE tool.
fluke_5282560
fluke_5282560_2
fluke_5282560_3
fluke_5282560_4
fluke_5282560_5
fluke_5282560
fluke_5282560_2
fluke_5282560_3
fluke_5282560_4
fluke_5282560_5

FLUKE MDA-550 serie III motor Drive Analyzer - 5282560

11,604.43 tax incl.
€9,590.44 excl. VAT (incl. all environmental contributions)
On order: delivered from 27/05/2026
each

  • Ordered before 20:00 - delivered as of 27/05/2026
  • Free shipping
  • Delivery by DHL

Scope of delivery

  • 1x BP 291 li-ion battery pack
  • 1x BC190 battery charger/mains adapter
  • 3x VPS421 100:1 high-voltage measuring probes with alligator clips
  • 1x VPS410-II-R 10:1 500MHz voltage measurement probe
  • 3x i400s AC current clamp
  • 1x SVS-500 shaft voltage kit (3x brush
  • Probe holder
  • Two-piece extension rod and magnetic base
  • Large protective carrying case with wheels (C437-II)
  • FlukeView-2 PC software (full version)
  • WiFi dongle

Product description

  • Guided testing with graphical, step-by-step connection diagrams
  • Preset measurement profiles reduce set-up complexity
  • Built-in functions for report writing
  • Easily produce troubleshooting reports of the situation in advance and afterwards

Make complex troubleshooting of motor drives simple. With guided test setups and automated drive measurements that produce reliable, repeatable test results.

The Fluke MDA 550 Motor Drive Analyzer saves you time. You no longer need to set up complex measurements and motor drive troubleshooting becomes much easier. Simply select a test and the step-by-step guided measurements show you where to make voltage and current connections. In addition, preset measurement profiles ensure that you record all the data you need for each critical part of the motor drive, from input to output, the DC bus and the motor itself. From simple to advanced measurements, the MDA-550 lets you handle it all. And with a built-in report generator, you can produce reliable before/after reports quickly and easily.

The MDA-550 is the ideal portable instrument for analysing motor drives. It helps you detect and fix common inverter motor drive problems.

  • Measure key motor drive parameters such as voltage, current, DC bus voltage level and AC ripple, voltage and current unbalance and harmonics, voltage modulation and voltage discharges through the motor shaft.
  • Perform comprehensive harmonics measurements to identify the effects of low and high harmonics on your electrical system.
  • Perform guided measurements at the motor drive input, DC bus, drive output, motor input and motor shaft with graphical, step-by-step voltage and current connection diagrams.
  • Use a simplified measurement setup with preset measurement profiles to automatically trigger data collection based on the selected measurement procedure.
  • Quickly and easily compile reports perfect for documenting troubleshooting and collaboration with others.
  • Measure additional electrical parameters with a full-featured 500MHz oscilloscope, a meter and recording function for a complete range of electrical and electronic measurements on industrial systems.

The Fluke MDA-550 Motor Drive Analyzer uses guided test measurements to make analysis easier than ever

Drive input

Measure input voltage and current to quickly see if values are within acceptable limits by comparing the drive's rated voltage to the actual supply voltage. Then check the input current to determine whether the current does not exceed the maximum value and the conductors are sufficiently sized. You can also check that the harmonic distortion is within an acceptable level by visually checking the shape of the waveform or by viewing the harmonic spectrum display, which shows both the total harmonic distortion and the individual harmonics.

Voltage and current unbalance

Check voltage unbalance at the inputs to make sure phase unbalance is not too high (> 6-8%) and that phase rotation is correct. You can also check for current unbalance, as excessive unbalance may indicate a problem with the drive rectifier.

Comprehensive measurements of harmonics

Excessive harmonics are a threat not only to your rotating machinery but also to other equipment connected to the electrical system. With the MDA-550, you can look for the harmonics of the motor drive but also discover the possible effects of the inverter's switching electronics. The MDA-550 has three ranges for harmonics, from the 1st to the 51st harmonic, from 1 to 9 kHz and from 9 kHz to 150 kHz, so you can detect any problem related to harmonic contamination.

DC bus

In a motor drive, the conversion from AC to DC in the drive is critical, as the correct voltage and adequate smoothing with low ripple is needed for the best performance of the drive. A high ripple voltage can be an indication of faulty capacitors or incorrect measurement of the connected motor. The record function can be used to monitor the performance of the DC bus dynamically in operating mode while a load is on.

Drive output

Check the drive output in terms of both voltage-to-frequency (V/F) ratio and voltage modulation. At high readings of the V/F ratio, the motor may overheat. At low readings of the V/F ratio, the connected motor may not be able to deliver the required torque for the load to adequately perform the intended process.

Voltage modulation

Measurements of the pulse width modulated signal are used to check for high voltage spikes that may damage the insulation of the motor windings. The rise time or steepness of pulses is indicated by the dV/dt value (the rate of voltage change over time). This should be compared with the specified insulation of the motor. The measurements can also be used to measure switching frequency to determine if there is a possible problem with electronic circuitry, or with grounding, where the signal rises and falls.

Motor input

Ensuring the voltage supply to the motor input is essential, and the choice of cabling from the drive to the motor is critical. An incorrect choice of cabling can lead to damage to both the drive and motor due to excessive reflected voltage spikes. It is important to check that the current at the connections is within the motor specification, as overcurrent can lead to overheating of the motor, which can shorten the life of the stator insulation and therefore cause premature motor failure.

Motor shaft voltage

Voltage pulses from a frequency-controlled drive can be induced by the stator of an electric motor into the rotor of the motor, leading to an electrical voltage in the rotor shaft. If this rotor shaft voltage is higher than the insulating capacity of the bearing grease, arcing can occur, leading to pitting and grooving in the motor bearing raceway: damage that can cause a motor to fail prematurely. The MDA-550 comes with carbon brush measurement pins that easily detect the presence of destructive spark currents, while the impulse amplitude and event count allow you to take action before failure occurs. By using this accessory, you can detect potential damage without investing in expensive permanently installed solutions.

Step-by-step guided measurements ensure you have the data you need, when you need it

The MDA-550 is designed to help you quickly and easily test and troubleshoot typical problems in three-phase and single-phase inverter motor drives. Thanks to the on-screen information and step-by-step guidance, you can easily configure the analyser and make drive measurements to quickly make better maintenance decisions. From the power supply to the installed motor, the MDA-550 provides the measurement capabilities for the fastest troubleshooting of motor drives.

Specifications / All features
  • Brand: FLUKE
  • EAN: 0195112021958
  • Supplier number: FLUKE 5282560
Questions about this product?
Contact our customer service.
Call, mail or chat with us!

Viewed products

⚠️
Connection lost
Oops! It looks like you lost your connection. Page was automaticaly reload.